Description

Magnetic Inductive Flow Meter

Product Specification

Display Remote
Automation Grade Manual
Operating Pressure 25 Kg/cm2
Line Size 15 NB to 300 NB
Connectivity RS485, USB
Meter Type Electronics
Condition New
Brand Flowtech
Model EMFM-0333
Measuring Range 0.5 m/sec for Minimum & 5m/sec for Maximum
Accuracy +- 1% FSD Optional: +-0.5% FSD.
Repeatability 0.3%

Product Description

FLOWTECH Make Electromagnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

 

Working Principle:

  • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Applications:

  • Scientific laboratory
  • Research centres
  • Chemical industries

Specifications:

  • Nominal Dia (mm): 15 to 400
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150C
  • Material of Construction : MS, SS 304, SS 316 & SS 316L
  • Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
  • Process Pressure : Max. 25 kg/cm2
  • Process Temperature : Max. 150C
  • Flow Tube Material : SS 316
  • End Connection : Flange/Wafer
  • Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
  • Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
  • Accuracy : ± 1% FSD Optional: ±0.5% FSD
  • Repeatability : 0.3%
  • Display : 2 Line Alfa Numeric LCD
  • Display Version : Integral /Remote
  • Display Unit : Standard Unit in M3, Litre
  • Power Supply : 230 VAC, 110 VAC & 24 VDC
  • Output : Std. 4 – 20 mA
  • Protection Class for Sensor : IP 65
  • Protection Class for Transmitter : IP 65
  • Cable Length for Remote : 10 meters